Skip to content

Error Codes

Error Codes:

This page provides all the Error Codes present in BRIGHTBLU Jolt Business chargers and the probable reasoning and solution to the same.

In case of any issues please feel free to contact us at [email protected] for any queries or support requirement.

Error CodeReason
UnderVoltageBRIGHTBLU Chargers support an input supply value of +/- 20% of 230V
OverVoltageBRIGHTBLU Chargers support an input supply value of +/- 20% of 230V
OverCurrentFailureCharger has detected that the current drawn is greater than max allowed (32A)
HighTemperatureCharger Temperature sensor detects an internal temperature greater than 80°C and has shut down to prevent further damage.
GroundFailureNeutral - Earth Voltage has exceeded permissible values (Maximum allowed 8V)
DiodeErrorDiode Failure detected at Vehicle end
VentErrorVentillation Error Failure detected at Vehicle end
OtherError:Includes the following sub-errors (vendorErrorCode):
  •EmergencyButtonEmergency Button is pressed
  •InputFrequencyErrorFrequency of Input Supply is not between 50/60 Hz
  •EarthLeakageErrorA current leakage of either 30mA AC or 6mA DC has been detected
  •PowerFailureLoss of input supply power(Will only work with BRIGHTBLU POWER BACKUP systems)
  •ModBusComsFailureLoss of communication with Energy Meter
  •VPRErrorInput Supply error (Phase Reversal or Asymetrical input supply)(Mostly with 3 Phase)
  •SDCardFailureInternal SD Card error(Logging and OTA updates disabled but charger will function normally otherwise)